VERTICAL PLATFORM LIFT INSTALLATION GUIDELINES
VERTICAL PLATFORM LIFT
INSTALLATION GUIDELINES
Criteria for both Residential
& Commercial Applications
-
Must be installed by a Licensed Elevator Contractor
-
Premier Lift Products, Inc. holds MN elevator contractor’s license #CE00130
-
-
Can require minor to major construction alterations
-
The State of Minnesota Requires Permits & Inspection by State Elevator Inspector
(Minneapolis and St. Paul each have separate elevator authorities) -
The state of Iowa requires permits & inspections on commercial applications only
-
The state of WI requires permits & inspections on all commercial applications and residential elevators, but not residential stair lifts or platform lifts
-
Require operation by constant pressure controls – Automatic operation is not allowed
-
Doors & gates must have special “Flush-Mount” frames with safety interlocks
-
Emergency telephone on the lift platform is required by code
-
ADA compliant phones with a dedicated line are required for all commercial applications
-
-
May be provided with same side, pass through or 90 degree configurations
-
Limited by code to no more than 14 feet of travel
-
Limited by code to a maximum load capacity of 750 pounds
-
Allowed by code to a maximum platform size of 18 square feet
-
Limited by code to a maximum speed of 30 feet per minute
-
Must have independent testing lab certification such as UL, CSA or ETL
-
Are required to meet all applicable Local, State & National codes

Proudly serving the Minneapolis/St. Paul Twin Cities metropolitan area, Central & Southern Minnesota, Northern Iowa and Western Wisconsin.
Additional Criteria for
Commercial Applications
-
Can provide vertical transportation to anyone with accessibility limitations – Vertical Platform wheelchair Lifts are not for use to carry freight
-
May require power door operators to meet code in certain configurations
-
Certain minimum platform sizes are required to meet code (and to comply with ADA guidelines)
-
Certain minimum push-button control sizes are required to meet code
-
Emergency ADA compliant telephone on the lift platform with dedicated line and 24 hour monitoring service.
-
Must be completely guarded with a full enclosure or full hoistway
-
Lighting with battery back-up above the lift enclosure or hoistway is required
-
Automatic re-leveling at the floor is required
-
Full time battery operation or battery back-up operation is typically required to meet code in commercial applications